Seven fabric duct models for air conditioning, ventilation, cleanrooms and fire-rated projects.

View all products

Airvex solutions

Airvex engineers survey the site, calculate airflow and choose the air distribution for each project.

Model AV-W · Multi-layer composite, thermal and acoustic insulation

Insulated fabric duct AV-W

A multi-layer composite insulated fabric duct that replaces insulated sheet-metal ducts: only 0.8–1.5 kg/m, around one tenth of galvanised steel duct, with good thermal insulation, sound absorption and airtightness. Factory-made to standard, with a QR code on every section.

0.8 – 1.5kg/m, 1/10 of sheet metal
3,000 Papressure resistance
5 – 45 mminsulation layer
1/10installation time vs sheet metal
Insulated fabric duct AV-W installed on a project
AV-W Project photo

Features

Why choose AV-W

Light: 0.8–1.5 kg/m

About one tenth of galvanised sheet-metal duct, reducing the load on the building structure.

High thermal insulation

Fire-rated rubber foam with low thermal conductivity and good moisture resistance; thickness chosen per location.

Low resistance, long throw

A smooth inner surface creates no turbulence and saves fan energy.

Sound absorbing

Soft materials that do not resonate; the insulation layer absorbs noise.

Airtight

Minimal leakage keeps the system efficient.

QR code on every section

Standardised factory production to the project design.

Fast zip connections

Sections join with zips and hang from cables; installation takes about one tenth of the time of traditional ducts.

Multi-layer fire protection

A2 and B1 fabric combinations, resistant to impact and abrasion.

Specifications

Technical data and air distribution

AV-W technical data

Weight
0.8 – 1.5 kg/m
Pressure resistance
3,000 Pa
Material
Composite: permanently fire-retardant fabric + insulation + hot-melt composite layer
Insulation
Rubber foam 5–45 mm or PE 3–30 mm
Fire class
A2 / B1 depending on the material combination
Cleaning
Washable
Cross-sections
RoundHalf-roundRectangular
Colours
WhiteGreyBlueGreenYellowRed
Suspension
Steel cable: single or multiple parallel rowsSteel pipe: single or multiple parallel rows
All shapes and suspension systems

Air distribution methods

AV-WInsulated nozzles

Insulated nozzles supply air over a long distance to defined positions.

AV-WDiffusers

Diffusers mounted on the duct spread air evenly over the zone below.

Construction

Six composite material combinations

The code gives the outer layer, the insulation and the inner layer: A = A2 glass-fibre fabric, B = B1 fabric, R = rubber foam, P = PE. The layers are bonded by a hot-melt composite layer.

A2 glass-fibre fabricB1 fire-retardant fabricRubber foam insulationPE insulation

W-ARB

A2 glass-fibre fabric + rubber foam insulation + B1 fabric

Rubber foam 5 – 45 mm

W-ARA

A2 glass-fibre fabric + rubber foam insulation + A2 glass-fibre fabric

Rubber foam 5 – 45 mm

W-BRB

B1 fabric + rubber foam insulation + B1 fabric

Rubber foam 5 – 45 mm

W-APB

A2 glass-fibre fabric + PE insulation + B1 fabric

PE 3 – 30 mm

W-APA

A2 glass-fibre fabric + PE insulation + A2 glass-fibre fabric

PE 3 – 30 mm

W-BPB

B1 fabric + PE insulation + B1 fabric

PE 3 – 30 mm

Applications

Where AV-W is used

1

Large spaces with suspended ceilings, supply from high level

  • Factories
  • Steel structures with load limits
  • Exhibition centres
2

Public and service buildings

  • Hospitals
  • Hotels
  • Administrative centres
  • Public buildings
3

Long throw in high spaces

  • Stadiums
  • Commercial centres
  • Airports and stations

In detail

About the Insulated fabric duct

Insulated sheet-metal ducts are heavy, slow to install and often need extra steelwork to carry them. AV-W is a composite fabric duct with the insulation built in: an outer fabric, a layer of fire-rated rubber foam or PE insulation and an inner fabric, bonded by a hot-melt composite layer. At 0.8–1.5 kg per metre it weighs about a tenth of an insulated steel duct.

Faster on site

Every section is produced in the factory to the project design and marked with its own QR code. On site the sections are joined with zips and hung from cables, so installation takes a fraction of the time of cutting, joining and insulating sheet metal. Air is released through insulated nozzles or diffusers mounted on the duct.

Six material combinations

Choose the outer layer, insulation and inner layer to match the fire and insulation requirements of each area: glass-fibre A2 fabric, B1 fabric, rubber foam 5–45 mm or PE 3–30 mm. The table above lists the six standard combinations.

AV-W is available round, half-round and rectangular. For the matching return air system, see AV-RW.

Installations

AV-W on site

Yellow AV-W insulated ducts in a factory
Yellow AV-W insulated ducts in a factory
AV-W with diffusers
AV-W with diffusers
AV-W branch ducts
AV-W branch ducts
AV-W with a large nozzle
AV-W with a large nozzle

Need a quotation for AV-W?

Send your layout, airflow and ceiling height. An Airvex engineer will select the size, air distribution and suspension, and prepare your quotation.