Fabric air distribution systems for HVACHotline: +81 70-9071-9616sale@fabricduct.net
Get a quote

Airvex fabric ducts

Seven fabric duct models for air conditioning, ventilation, cleanrooms and fire-rated projects.

View all products

Airvex solutions

Airvex engineers survey the site, calculate airflow and choose the air distribution for each project.

Model AV-RW · Framed insulated fabric duct for negative pressure

Insulated return air fabric duct system AV-RW

A return air duct system made of insulated fabric with an inner support frame that withstands negative pressure, replacing traditional sheet-metal return ducts. Light, hung like a fabric supply duct and matched to the supply system, with multi-point return for even air circulation.

3,000 Papressure resistance
Negativeframe rated for negative pressure
5 – 45 mminsulation layer
Multi-pointeven return air
Insulated return air fabric duct system AV-RW installed on a project
AV-RW Project photo

Features

Why choose AV-RW

Frame rated for negative pressure

A strong inner frame keeps the duct from collapsing under suction.

Multi-point return

Air is drawn back at many points along the run, so the room air circulates evenly.

Clean return air

Return openings with filter mesh stop dust before it reaches the unit.

High thermal insulation

Fire-rated rubber foam with high thermal resistance.

Sound absorbing

The insulation layer absorbs noise for quiet operation.

Composite, 3,000 Pa

Multi-layer permanently fire-retardant fabric.

Light and quick to install

Hung the same way as fabric supply ducts.

Energy saving

Lower heat loss on the return path and environmentally friendly.

Specifications

Technical data and return air

AV-RW technical data

Pressure resistance
3,000 Pa
Construction
Insulated composite fabric + inner support frame
Insulation
Rubber foam 5–45 mm or PE 3–30 mm
Fire class
A2 / B1 depending on the material combination
Compatibility
Matched to Airvex fabric supply ducts
Cross-sections
RoundRectangular
Colours
WhiteBlackGreyBlueGreenYellowRed
Suspension
Steel cable: single or multiple parallel rowsSteel pipe: single or multiple parallel rows
All shapes and suspension systems

Return air options

AV-RWLaser-cut return holes

Return holes along the duct draw air evenly from many points.

AV-RWFiltered return diffusers

Diffuser-type return outlets with integrated filter mesh.

AV-RWReturn grilles with filter

Rectangular return grilles with dust filter mesh.

Construction

Six composite material combinations

The code gives the outer layer, the insulation and the inner layer: A = A2 glass-fibre fabric, B = B1 fabric, R = rubber foam, P = PE. The layers are bonded by a hot-melt composite layer and held by an inner support frame.

A2 glass-fibre fabricB1 fire-retardant fabricRubber foam insulationPE insulation

RW-ARB

A2 glass-fibre fabric + rubber foam insulation + B1 fabric + inner support frame

Rubber foam 5 – 45 mm

RW-ARA

A2 glass-fibre fabric + rubber foam insulation + A2 glass-fibre fabric + inner support frame

Rubber foam 5 – 45 mm

RW-BRB

B1 fabric + rubber foam insulation + B1 fabric + inner support frame

Rubber foam 5 – 45 mm

RW-APB

A2 glass-fibre fabric + PE insulation + B1 fabric + inner support frame

PE 3 – 30 mm

RW-APA

A2 glass-fibre fabric + PE insulation + A2 glass-fibre fabric + inner support frame

PE 3 – 30 mm

RW-BPB

B1 fabric + PE insulation + B1 fabric + inner support frame

PE 3 – 30 mm

Applications

Where AV-RW is used

1

Large spaces with suspended ceilings

  • Factories
  • Commercial centres
  • Exhibition centres
2

Public and service buildings

  • Hospitals
  • Administrative centres
  • Public buildings
3

High spaces that need even return air

  • Stadiums
  • Airports and stations
  • High-bay workshops

In detail

About the Insulated return air fabric duct system

Fabric ducts are normally used for supply air because the air pressure keeps them inflated. Return air works the other way round: the fan pulls air out of the duct, so an ordinary fabric duct would collapse. AV-RW solves this with a strong inner frame that holds the insulated fabric in shape under negative pressure.

Even return, clean air

Instead of one or two large return grilles, AV-RW draws air back through laser-cut holes, filtered diffusers or grilles distributed along the run. The room air circulates evenly, stagnant zones are avoided and the filters catch dust before it reaches the air handling unit.

A complete fabric system

AV-RW uses the same composite insulation as AV-W (six material combinations, rubber foam 5–45 mm or PE 3–30 mm) and is hung the same way, so supply and return can be designed, supplied and installed as one light-weight system. It is available round or rectangular.

Send us the return airflow and layout, and we will propose the return points and duct sizes.

Installations

AV-RW on site

AV-RW return ducts under a steel roof
AV-RW return ducts under a steel roof
AV-RW run along the roof trusses
AV-RW run along the roof trusses
Rectangular AV-RW under the ceiling
Rectangular AV-RW under the ceiling
Vertical AV-RW return section
Vertical AV-RW return section

Need a quotation for AV-RW?

Send your layout, airflow and ceiling height. An Airvex engineer will select the size, air distribution and suspension, and prepare your quotation.